Railway Cables | ||||||||||
|
G7623 Trackside Communications Cables
Application
The cables are designed for limited fi re hazard applications for internal use within stations, buildings and
equipment rooms.
Standards
LUL Spec G7623 A2
Construction
Conductors
Tinned annealed solid copper, 0.5/0.6/0.63 mm nominal diameter.
Insulation
LSZH Insulation.
Cabling Element
Two insulated conductors are twisted together to form a pair.
Stranding
Cables are composed of unit stranding.
Core Wrapping
Non-hygroscopic plastic tape with overlapping.
Outer Sheath
LSZH sheath.
Electrical Characteristics at 20℃
Nominal Conductor Diameter | mm | 0.5 | 0.6 | 0.63 |
---|---|---|---|---|
Maximum Conductor Resistance | Ω/km | 98 | 68 | 58 |
Minimum Insulation Resistance @500 V DC | MΩ.km | 120 | 120 | 120 |
Maximum Average Mutual Capacitance @1KHz | nF/km | 80 | 80 | 80 |
Maximum Average Capacitance Unbalance @800Hz pair-to-pair | 500 | 500 | 500 | |
Test Voltage AC 1min | V | 500 | 500 | 500 |
Mechanical and Thermal Properties
Minimum Bending Radius: 7.5×OD
Temperature Range: -30℃ to +70℃ (during operation);
-10℃ +55℃ (during installation)
Core Identification
Pair Number |
A Wire | B Wire | Pair Size | 20 Pair | 40 Pair | 80 Pair | 100 Pair | 160 Pair | 320 Pair |
---|---|---|---|---|---|---|---|---|---|
Number of Units | |||||||||
Center | 1 | 2 | 1 | 3x1/2 | 2 | 1 | |||
1st Layer | 6x1/2* | 7x1/2 | 6 | 5 | |||||
2nd Layer | 10 | ||||||||
1 | WHITE | BLUE | 1 | ORANGE | ORANGE | ORANGE | BLUE | ORANGE | ORANGE |
2 | WHITE | ORANGE | 2 | GREEN | ORANGE | ORANGE | GREEN | ORANGE | |
3 | WHITE | GREEN | 3 | NATURAL | GREEN | ORANGE | NATURAL | ||
4 | WHITE | BROWN | 4 | GREEN | BROWN | NATURAL | NATURAL | ||
5 | WHITE | GREY | 5 | GREY | NATURAL | NATURAL | |||
6 | RED | BLUE | 6 | WHITE | NATURAL | GREEN | |||
7 | RED | ORANGE | 7 | RED | NATURAL | ORANGE | |||
8 | RED | GREEN | 8 | BLACK | GREEN | NATURAL | |||
9 | RED | BROWN | 9 | YELLOW | NATURAL | ||||
10 | RED | GREY | 10 | VIOLET | NATURAL | ||||
11 | BLACK | BLUE | 11 | NATURAL | |||||
12 | BLACK | ORANGE | 12 | NATURAL | |||||
13 | BLACK | GREEN | 13 | NATURAL | |||||
14 | BLACK | BROWN | 14 | NATURAL | |||||
15 | BLACK | GREY | 15 | NATURAL | |||||
16 | YELLOW | BLUE | 16 | GREEN | |||||
17 | YELLOW | ORANGE | |||||||
18 | YELLOW | GREEN | |||||||
19 | YELLOW | BROWN | |||||||
20 | YELLOW | GREY |
*1/2 refers to units of 10 Pairs
Dimensions And Weight
Cable Code | No. of pairs | Minimum Sheath Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
---|---|---|---|---|
0.5mm Conductor, 0.82mm Insulated Wire | ||||
RS7623A2-HH-1P0.5 |
1 | 1.3 | 6.0 | 30 |
RS7623A2-HH-2P0.5 |
2 | 1.3 | 7.0 | 45 |
RS7623A2-HH-3P0.5 |
3 | 1.4 | 7.0 | 50 |
RS7623A2-HH-6P0.5 |
6 | 1.5 | 9.0 | 61 |
RS7623A2-HH-10P0.5 |
10 | 1.6 | 11.0 | 107 |
RS7623A2-HH-20P0.5 |
20 | 1.9 | 14.0 | 190 |
RS7623A2-HH-40P0.5 |
40 | 1.9 | 16.0 | 320 |
RS7623A2-HH-80P0.5 |
80 | 2.2 | 23.0 | 640 |
RS7623A2-HH-100P0.5 |
100 | 2.2 | 25.0 | 760 |
RS7623A2-HH-160P0.5 |
160 | 2.6 | 29.0 | 1150 |
0.6mm Conductor, 1.12mm Insulated Wire | ||||
RS7623A2-HH-1P0.6 |
1 | 1.4 | 6.0 | 35 |
RS7623A2-HH-2P0.6 |
2 | 1.4 | 7.0 | 50 |
RS7623A2-HH-3P0.6 |
3 | 1.5 | 7.0 | 60 |
RS7623A2-HH-6P0.6 |
6 | 1.6 | 9.0 | 85 |
RS7623A2-HH-10P0.6 |
10 | 1.7 | 11.0 | 145 |
RS7623A2-HH-20P0.6 |
20 | 2.2 | 14.0 | 245 |
RS7623A2-HH-40P0.6 |
40 | 2.2 | 18.0 | 410 |
RS7623A2-HH-80P0.6 |
80 | 2.8 | 25.0 | 830 |
RS7623A2-HH-100P0.6 |
100 | 2.8 | 27.0 | 980 |
RS7623A2-HH-160P0.6 |
160 | 3.2 | 33.0 | 1450 |
0.63mm Conductor, 1.15mm Insulated Wire | ||||
RS7623A2-HH-1P0.63 |
1 | 1.4 | 5.5 | 40 |
RS7623A2-HH-3P0.63 |
3 | 1.5 | 7.3 | 70 |
RS7623A2-HH-5P0.63 |
5 | 1.6 | 8.5 | 89 |
RS7623A2-HH-6P0.63 |
6 | 1.6 | 8.9 | 100 |
RS7623A2-HH-10P0.63 |
10 | 1.7 | 11.1 | 170 |
RS7623A2-HH-12P0.63 |
12 | 1.7 | 11.6 | 195 |
RS7623A2-HH-160P0.63 |
160 | 3.2 | 35.0 | 1595 |